A 2 g turn will see objects falling to the floor at twice the normal acceleration of gravity.
Floor load limit aircraft.
Next consult a span table to cross reference the spacing and span to find the required fb value for that table s load limits.
Box 2 was already ruled out.
Either of boxes 3 and 4 with their longest length parallel to the aircraft longitudinal axis correct.
Floor running load or linear load.
If a mass of 50 kg is spread over 1 square metre the distribution load is 50 1 50 kg sq meter.
Base of container 20 in x 20 in 400 sq in floor loading 100 lb 0 2 lb per sq in 400 sq in or 0 25 lb sq in x 144 36 ib sq ft.
It is calculated as the weight of the object divided by the distance it covers along the aircraft s length.
The maximum weight the floor can sustain per square inch foot as provided by the manufacturer.
It is calculated by dividing the load by the area it covers.
The aircraft floor is a precision engineered structure any excess of concentrated mass in one location can cause damage to this structure both endangering the safety of the aircraft and leading to expensive and extensive repairs to the aircraft.
An amount of weight higher than this amount is assumed to damage the uld and hence endanger the safety of the aircraft.
For example an observer on board an aircraft performing a turn with a load factor of 2 i e.
Floor loading is the weight of a load ill pounds divided by the area of floor space which the load occupies.
The span table for a 30 psf live load 10psf dead load floor indicates a required fb value of 1 315 and a minimum e value of 1 800 000.
Lineman standing on one leg will fall through the floor.
14 cfr 1 1 16g abbreviation acronym aerodynamics aircraft airline airlines airport airports airworthiness amt atc aviation safety aviation weather avionics bird strike engineering etops faa faa pilot s handbook flying human.
The cargo compartment floor is designed for an evenly distributed load of 732 kg m2 of bulk loads with a maximum load density of 240 kg m3.
Floor load capacity limit is the maximum permissible load per square meter.
In the example the joists have a spacing of 16 inches and a span of 11 feet 2 inches.
Calculating distribution load intensity.
A uniform load rating on a beam can easily be translated into what an equivalent maximum point load can be.
It does not mean that a 300 lb.
For 1 sq meter area in contact with the floor the limit is 731 for 0 8 sq meter the limit is 731 x 0 81 585 kgs.
The floor loading for a 100 pound container is determined as follows.
Furthermore certain types of uld most specifically 16 and 20 foot pallets have specific maximum.
The standard used by lufthansa is 2000 kg per square meter.
In general whenever the term load factor is used it is formally correct to express it using numbers only as in a maximum load factor of 4.