What is the resistance of the floor sensor circuit for the aube th232 underfloor heating thermostat.
Floor sensor resistance.
This video shows you how to test the resistance of your sensor probe correctly to identify any faults.
Warmup heating cables are constant wattage cables that should be tested on a 200 ohm scale.
Replacement floor temperature sensor suitable for a wide range of underfloor heating thermostats.
Suitable for use in wet areas ip68.
Set the multimeter for resistance at 10k ω 2 at room temperature and take a reading between the sensor leads.
The slab sensor 079 is commonly used for floor temperature sensing in floor heating applications.
Works with a wide range of different thermostatsplease check the resistance values of your current sensor against the table below for compatibility 3 metre long cable cable has high rigidity allowing it to be easily passed through existing flexible conduit suitable for use in wet areas.
Secure floor sensor probe.
Test the floor temperature sensors using a multimeter to verify accuracy of the sensors.
Ensure the probe s tip is located in an area that can represent the overall floor temperature and away from other heating cooling sources.
All electrical work should be carried out by a qualified professional and adequate.
To answer your question the resistance reading will be different on different floor probes the sensor and stat resistance readings must match in order for the system to operate correctly.
Every comfortzone electric underfloor heating thermostat should be set up with a floor temperature sensor probe to monitor the temperature of your floor.
3 meter floor temperature sensor probe for underfloor heating thermostat features works with a wide range of different thermostats.
This sensor is designed to provide a thermostat with the ability to maintain a minimum slab temperature or help to limit the maximum slab temperature.
10k ntc th232 resistance sensor circuit resistance.
Please check the resistance values of your current sensor against the table cable has high rigidity allowing it to be easily passed through existing flexible conduit.
The probe s tip should be between the heating wires.
Perform insulation and resistance test on page 6.
To ensure that your floor heating system will function properly always test the resistance of your wires with a digital multimeter set to 200 ohms before during and after installation.
Test 4 temperature sensor.
The resistance will vary according to the temperature i e the colder the sensor the higher the resistance.
Describes the situation the problem occurs or the environment that the question applies to including products affected.
Duct tape the floor sensor probe on top of the nuheat mat.
Every comfortzone electric underfloor heating thermostat should be set up with a floor temperature sensor probe to monitor the temperature of your floor.